Cal Station
Cal Station software may
either be used on a stand-alone computer, or as the first Cornerstone station in
a networked configuration. The install procedure for the Cal Station software
includes user choices for the location of the common Cornerstone program and
data files. They may be located on a dedicated LAN server station or on any
network drive on the LAN. The computer designated as the
Cornerstone File Server
cannot run the Cornerstone application software, but can run other programs.
The computer where the initial installation takes
place has a special status in the system and is called the
Home Cal Station.
Common service programs, required for operation of all Cornerstone
stations on the LAN, will reside and execute on the Home Cal Station. Other
optional Cornerstone libraries, for use throughout the network, are installed
only through the Home Cal Station. Those libraries will reside on the same
network drive as the Cal Station program and database files
(i.e. the Cornerstone File Server). Software registration and
authorization for the whole multi-user system takes place only through the Home
Cal Station.
Multi-user Kits
Three optional Multi-user
Kits add Cornerstone stations (called SubStations) to the Home Cal Station
described above. Kits are purchased separately and are
available in three sizes, providing a total of 3 users, 6 users,
or 10 users. With the exception of a few network
administration functions, SubStations provide all of the functions of a
stand-alone Cal Station or the Home Cal Station. They can perform directed
calibrations, manual calibration data entry, and calibrator docking.
Substations must meet Cal Station hardware platform requirements except that
minimal hard disk space is required. Multi-user kits include a Server install
disk, a SubStation install disk, a Multi-user kit install disk, and an
installation manual. With all Multi-user kits, you can install SubStation
software on any number of computers on your LAN. The 3, 6, or 10 user kit size
limits only the number of simultaneous active Cal Station users on the network.
User Manuals
Use of the SubStation software is identical to that
documented in the
User’s Manual for Cornerstone Cal Station,
which is included with the single Cal Station model. Additional User’s Manuals
for use with SubStations are ordered separately in the quantity you require.
Optional CalLibs
Optional CalLibs may be added to a networked
Cornerstone system. Just as with a stand-alone system, multiple types of
CalLibs may be used on the same networked system. You need purchase only a
single licensed copy of each CalLib type for use on a networked system. Each
CalLib is installed only once through the Home Cal Station, and the CalLib
program files reside on the Cornerstone File Server.
Multi-user System Requirements
Cornerstone File
Server
Cornerstone program files
and global system database files may be installed on a dedicated LAN server
station or they may be installed on any suitable server or
other station on the LAN. The computer where these files reside must be
running Microsoft Windows NT Server 4.0, Windows 98, Windows 2000,
or Windows XP. The computer where the common Cornerstone files reside
cannot run the Cal Station application. The server computer can run other
applications or act as a file server for other applications. This Cornerstone
File Server also hosts the license (key) server that administers multi-user
operation of the Cal Station software.
Windows
Compatibility
All Cornerstone stations
(Home Cal Station and SubStations) must be running Microsoft Windows 98,
Windows ME, Windows
NT Workstation 4.0, Windows 2000, or Windows XP.
Network Protocol
The Cornerstone File
Server, Home Cal Station and SubStation computers should be set up to run the
TCP/IP protocol or the standard Microsoft NetBEUI Network protocol. One of
these protocols can normally coexist on the same hardware platforms and network
cable with other network protocols and file servers (e.g. IPX/SPX). A
multi-user Cal Station system can be set up that does not run either of these
protocols, but such a configuration will yield slower data access response
times, making it advantageous to run the TCP/IP or NetBEUI protocol.
Network Hardware
LAN hardware and driver
software must be compatible with Windows software.
Prerequisites
for SubStation Operation
The server computer where
the Cornerstone program files and global system database files are located
(designated the Cornerstone File Server), and the computer where the Home
Cal Station software is installed, must both be operating in order for
any other Cornerstone LAN SubStations to operate.
Disk Requirements
On the Cornerstone File Server, program files can
require up to 15 MB. Also on the Server, database file space needs are dictated
by your instrument population and the extent of historical record storage
desired. Typically, a 1000 instrument database, storing up to 25 history
records per instrument, requires about 200 MB. Each SubStation requires
only about 3 MB for local files.
Operational Considerations
Local Area
Network
Cornerstone Multi-user
configurations have been designed and tested for correct performance on
local
area networks (LANs). Wide Area Network (WAN) operation may be feasible but was
not a specific design objective and is not supported. Note that use of the
NetBEUI protocol is not compatible with routers and other equipment normally
associated with long distance network connections.
Password
Security and SubStation Configurability
Normal Cornerstone user
password security is provided on the Multi-user system. The user and password
tables are global for the entire LAN system. There is no restriction as to
which user may sign on to which station on the LAN. The software does provide
the Cornerstone System Manager user with the ability to configure each
SubStation location for the major function windows that it displays. With this
feature, you can restrict certain functions to certain SubStations. For
example, you could designate which stations allow calibrator docking.
Read-only Users
The user password and
security level system of Cornerstone software allows a SubStation, based on the
security level of the signed on user, to act as a read-only station on the
network. The “Restricted” security level allows read-only access to the
Cornerstone database. It also provides the ability to print reports and to
export data from the database into .CSV files for use by other applications.
Restricted users cannot make any database changes and cannot connect to any
calibrators.
Event Log
The Cal Station Event Log
is maintained local to each station on the network.
Response Time
Performance
Software response time
performance on a LAN is a function of hardware capabilities, the activity on
each Cornerstone station, other activity on the LAN, and loads on the Server
from other applications. For best Cal Station performance, the TCP/IP or
NetBEUI network protocols should be used, in addition to any other network
protocols that your network applications may require.